Skip to main content

Volvo EC330B Excavator Engine Start and Stop Circuit Old Overview

Volvo EC330B Excavator Engine Start and Stop Circuit Old Overview 

Volvo PTT


Procedures:
Engine Start and Stop Circuit(Old)
Power from battery => electric greasing system,start key,start motor,battery relay
Power from battery relay =>safety start relayVocom 88890300
1) Key ON
 BR=> Battery relay,alternator(15,pre-magnetization)
 ACC=>VECU,Air conditioner,EMS power relay
2) Key Start
 R2=> VECU
 C=> safety start relay
3) Engine running
 Alternator(L)=>hour meter,safety start relay,VECU(charge lamp off)
 * Resistor between alternator and BR termainal for quick charge lamp off
 Alternator(B+)=>alternator(BS,voltage sensing for regulation)
 Alternator(15)=>battery relay
4) Key Off
 VECU(JA61)=>battery relay

Comments

Popular posts from this blog

Volvo EC330B Excavator Battery Relay & Safety start Relay

Volvo EC330B Excavator Battery Relay & Safety start Relay Battery relay This is main relay for electric system. Volvo PTT Techtool 2.8.130 The relay turns the battery current ON or OFF, according to low power signals received from the start switch. Use of the relay permits the start switch to control the power of the batteries with a small capacity wire. When you replace this component, pay attention to the +/- signs on the relay. Wrong connection can cause early failure of relay. 2. Safety start relay When trying to restart the engine while the engine is running, or if the start switch is in the START position after the engine is activated, the relay cuts off the current to the starter motor to protect it.

Volvo EC330B Excavator Electronic Control System Overview

Volvo ECB330B Excavator Electronic control system overview   Volvo ECB330B Electronic control system is composed of various computers and its communication line. In our system, 2 computer (EECU, VECU) is programmable and 1 computer (MDU) is not. Volvo Tech Tool Communication is important thing to control the machine properly. We use two communication lines that is international protocol. The line is twisted to protect the bus from electrical interference.