Safe start and stop control
The optimal condition of engine start and stop is automatically set by this function. The engine can be protected from damages that may occur at engine start and stop condition.Volvo Vocom 1


1. During starting engine, Engine rpm is fixed to low idle (I2) regardless of engine rpm control switch position to protect engine from sudden rpm increase in cold period or other situation.Volvo PTT



2. During starting, if safety lever is up, this signal disengage starter to prevent from sudden movement of hydraulic function.


3. After starting, any attachment operation or speed control switch operation makes engine return to the speed set by rpm control switch.
4. When start switch is turned off,
- Start switch signal is transferred to E-ECU.
- Important data are saved to ECUs.
- EMS power cut off relay is off.
- V-ECU cut-off power to battery relay.
- Whole system power will be off.

More repair for Volvo,please refer to:Volvo Trouble Repair

Comments

Popular posts from this blog

Volvo EC330B Excavator Battery Relay & Safety start Relay

Volvo EC330B Excavator Battery Relay & Safety start Relay Battery relay This is main relay for electric system. Volvo PTT Techtool 2.8.130 The relay turns the battery current ON or OFF, according to low power signals received from the start switch. Use of the relay permits the start switch to control the power of the batteries with a small capacity wire. When you replace this component, pay attention to the +/- signs on the relay. Wrong connection can cause early failure of relay. 2. Safety start relay When trying to restart the engine while the engine is running, or if the start switch is in the START position after the engine is activated, the relay cuts off the current to the starter motor to protect it.

Volvo EC330B Excavator Electronic Control System Overview

Volvo ECB330B Excavator Electronic control system overview   Volvo ECB330B Electronic control system is composed of various computers and its communication line. In our system, 2 computer (EECU, VECU) is programmable and 1 computer (MDU) is not. Volvo Tech Tool Communication is important thing to control the machine properly. We use two communication lines that is international protocol. The line is twisted to protect the bus from electrical interference.

Volvo EC330B Excavator Engine Start and Stop Circuit Old Overview

Volvo EC330B Excavator Engine Start and Stop Circuit Old Overview  Volvo PTT Procedures: Engine Start and Stop Circuit(Old) Power from battery => electric greasing system,start key,start motor,battery relay Power from battery relay =>safety start relay Vocom 88890300 1) Key ON  BR=> Battery relay,alternator(15,pre-magnetization)  ACC=>VECU,Air conditioner,EMS power relay 2) Key Start  R2=> VECU  C=> safety start relay 3) Engine running  Alternator(L)=>hour meter,safety start relay,VECU(charge lamp off)  * Resistor between alternator and BR termainal for quick charge lamp off  Alternator(B+)=>alternator(BS,voltage sensing for regulation)  Alternator(15)=>battery relay 4) Key Off  VECU(JA61)=>battery relay